MK11 传感器(铜)
描述
MK11系列为磁场驱动干簧传感器,密封于一个螺纹表面外壳。安装产品的螺纹开口位于感测区域内。此螺纹式外壳及其附件在极点开关、端点位置、接近感测应用中易于准确调节。
此传感器应安装于一个固定的表面,驱动磁铁安装于活动的表面。靠近或远离磁场将决定干簧开关的吸合或断开。磁场吸合/断开灵敏度被分成五个AT范围。您可选择不同开关、端子和线缆长度。
产品符合RoHS标准。
特性
- 稳固机械外壳,可抵抗更高力矩、压力、潮湿
- 非铁磁外壳可消除切换干扰
- 多个公制&标准螺纹尺寸
- SPST & SPDT
- 多种外壳材料
- 可定制线缆端子
- 准确感测调整
- 可在高温下工作
- 干簧开关是密封设计,可在污染环境中工作
- 动态测试触点
- 数百万次可靠操作
应用
- 自动卫星天线
- 门用感测
- 电梯控制
- 线性驱动装置中的端极运动感测
- 工业
- 活塞终端行程与位置感测
- 接近和极限开关
- 机械化系统
- 安全控制
规格
| 触点形式 | 1A, 1B, 1C |
| 额定功率 (W) | 0 至 100 |
| 切换电压 (VDC) | 0 至 1000 |
| 切换电流 (A) | 0 至 1.5 |
| 通电电流 (A) | 0 至 2.5 |
| 击穿电压 (最小 VDC) | 100 至 2000 |
| 磁场灵敏范围 (AT) | 5 至 70 |
产品搜索
| Item no. | Description | Contact - form | Switching voltage V | Switching current A | Pull- In excitation (Reference value) AT | Grid dimension - THD MM | Contact rating W | Carry current A | Operating temperature GRAD C | |
|---|---|---|---|---|---|---|---|---|---|---|
| 9112661054 | A - NO | 200 V | 0.5 A | 10-15 AT | 10 W | 1.25 A | -5-70 GRAD C | |||
| 9112902034 | B/C - NC | 175 V | 0.5 A | 10-15 AT | 10 W | 1 A | -5-70 GRAD C | |||
| 9113903054 | Form C - Changeover | 175 V | 0.5 A | 10 W | 1 A | -5-80 GRAD C | ||||
| 9114661054 | A - NO | 200 V | 0.5 A | 20-25 AT | 10 W | 1.25 A | -5-70 GRAD C | |||
| 9116612903 | A - NO | 180 V | 0.5 A | 20-25 AT | 10 W | 1.25 A | -5-80 GRAD C | |||
| 9116613676 | A - NO | 180 V | 0.5 A | 10-15 AT | 10 W | 0.5 A | -5-80 GRAD C | |||
| 9116613677 | A - NO | 180 V | 0.5 A | 10-15 AT | 10 W | 0.5 A | -5-80 GRAD C | |||
| 9116613679 | A - NO | 180 V | 0.5 A | 10-15 AT | 10 W | 0.5 A | -5-80 GRAD C | |||
| 9116614753 | A - NO | 180 V | 0.5 A | 10-15 AT | 10 W | 0.5 A | -5-80 GRAD C | |||
| 9118066104 | A - NO | 180 V | 0.5 A | 20-25 AT | 10 W | 1.25 A | -5-80 GRAD C | |||
| 9118266054 | A - NO | 180 V | 0.5 A | 10-15 AT | 10 W | 1.25 A | -5-80 GRAD C | |||
| 9118346054 | A - NO | 200 V | 0.5 A | 15-20 AT | 10 W | 1 A | -5-80 GRAD C | |||
| 9118366054 | A - NO | 180 V | 0.5 A | 15-20 AT | 10 W | 1.25 A | -5-80 GRAD C | |||
| 9118385054 | 500 V | 100 W | 1 A | -5-80 GRAD C | ||||||
| 9118393054 | Form C - Changeover | 175 V | 0.5 A | 10 W | 1 A | -5-80 GRAD C |
技术文献
基本原理
干簧产品的保护
运用领域
库存查询
Stock Check
| Item no. | Distributor | Region | Quantity | Cart | RFQ | Inventory Date |
|---|---|---|---|---|---|---|
| MK11-BV50921 | MASTER DISTRIBUTORS | North America | 10 | RFQ | 2012/05/24 | |
| MK11/B10-1A66B-500W | DIGI-KEY CORPORATION | North America | 49 | RFQ | 2012/05/24 | |
| MK11/B10-1A66B-500W | MOUSER ELECTRONICS | North America | 10 | RFQ | 2012/05/24 | |
| MK11/B12-1A66B-500W | DIGI-KEY CORPORATION | North America | 50 | RFQ | 2012/05/24 | |
| MK11/B12-1A66B-500W | MOUSER ELECTRONICS | North America | 7 | RFQ | 2012/05/24 | |
| MK11/B6-1A66B-500W | DIGI-KEY CORPORATION | North America | 50 | RFQ | 2012/05/24 | |
| MK11/B6-1A66B-500W | MOUSER ELECTRONICS | North America | 12 | RFQ | 2012/05/24 | |
| MK11/B8-1A66B-500W | MOUSER ELECTRONICS | North America | 95 | RFQ | 2012/05/24 | |
| MK11/B8-1A66B-500W | DIGI-KEY CORPORATION | North America | 94 | RFQ | 2012/05/24 | |
磁铁运动
延伸产品
常见问题
干簧传感器
Are the hall, reed or emr sensors affected by EDI/RFI?
Are the hall, reed or emr sensors hermetically sealed?
What is the output dielectric strength for hall, reed or emr sensors?
What is the output capacitance for hall, reed or emr sensors?
What is the release time for hall, reed or emr sensors?
What is the operate time for hall, reed or emr sensors?
How much current can be switched directly for hall, reed or emr sensors?
What is the output voltage range for hall, reed or emr sensors?
How much power can you switch direcly with the hall, reed or emr sensors?
Can one switch loads directly for hall, reed or emr sensors?
What is the output on resistance for hall, reed or emr sensors?
Is hysteresis adjustable for hall, reed or emr sensors?
Is output polarity sensitivity critical for hall, reed or emr sensors?
Are external circuits required for hall, reed or emr sensors?
Is input polarity sensitivity an issue with hall, reed or emr sensors?
Is an applied current required for a change of state with a hall, reed or EMR sensor?
Does a Hall Sensor require extra circuitry?
What is Hall Effect?
What switch do I use when switching 5-15 Volts with 10 to 50 milliamps?
What switch do I use when switching 15-35 Volts with 10 to 250 milliamps?
What reed switch do I use for low level switching?
What reed switch do I use for low level switching?
Small electromechanical relays are not good for switching low levels of voltages and currents. Electromechanical relays need a hefty voltage and/or current to break any film buildup. It is this film buildup that won't allow very low voltages and currents to pass through the contacts. Reed switches are clearly the best. Using sputtered ruthenium contacts or iridium contacts are the best materials for these low level loads.
When do you use an evacuated reed switch?
How much voltage can a pressurized reed switch effectively open?
How much voltage can a pressurized reed switch effectively open?
Miniature reed switches less than 20 mm (0.80 inches) glass length can effectively break up to 250 Volts. This depends on the pull-in AT (mT) used. The higher the better. Reed switches less than 10 mm will shrink this value to around 150 volts. Minimizing the current flow at the time of opening will improve this value.
What is the signature of a load?
What is the signature of a load?
Reed switches whether they are used in sensors or relays all will be asked to switch some load. Generally there are two aspects to this load.
- Its steady state load
- Is the actual switching taking place during the first 50 nanoseconds. This is also called the the signature of the load.
How do I know what reed switch to select?
How do I know what reed switch to select?
There are several key factors:
- You need to have an idea of the required load. What voltage and current is being switched at the time of closure for the first 50 nanoseconds?
- How many operations will be required during the life of the product?
- What are the size requirements? How much room is needed?
- How will the product be mounted? Surface mount, thru hole, etc.
- For long life and low levels, use a ruthenium or an iridium sputtered/plated switch.
- For switching applications from 50 Volts to 200 volts use the Philips/Coto/Comus sputtered ruthenium switch.
- For switching currents 25 ma to 1 amp, the OKI thickly plated rhodium is good along with our STM10 SKS-1A35.
- For higher voltages above 200 volts up to 4000 volts at relatively low current use the OKI ORD2210V.
- For voltages above 1000 volts up to 10,000 volts with higher currents use the Hermetic vacuum switches. This represents a start. One could write a book on this subject. Best to find out the exact customer load and run a life test with a few or several reed switches to make the final determination.
Can a magnet packaged with a reed switch be turned into a temperature sensor?
Can a magnet packaged with a reed switch be turned into a temperature sensor?
A magnet and reed switch can be turned into a temperature sensor by using a magnet that has a certain curie temperature for the temperature you want to sense. When that curie temperature is reached the magnet loses its magnetic properties whereby the reed switch contacts open. When the temperature drops below the curie temperature, the reed contacts will close.
在我们的常见问题解答中未找到您所关注的问题吗?请填写“联系表格”来提交新问题。